imx: ahab: allow to bypass confirmation for ahab_close cmd
Calling ahab_close cmd force the user to interact for confirmation. This is not user-friendly when using this cmd during factory process. Allow the user to pass '-y' option to bypass this confirmation. Signed-off-by: Clément Péron <peron.clem@gmail.com> Reviewed-by: Peng Fan <peng.fan@nxp.com> Acked-by: Oliver Graute <oliver.graute@kococonnector.com>
This commit is contained in:
committed by
Stefano Babic
parent
717bf50f4b
commit
7d6a36a48d
@@ -303,10 +303,11 @@ static int confirm_close(void)
|
||||
static int do_ahab_close(struct cmd_tbl *cmdtp, int flag, int argc,
|
||||
char *const argv[])
|
||||
{
|
||||
int confirmed = argc >= 2 && !strcmp(argv[1], "-y");
|
||||
int err;
|
||||
u16 lc;
|
||||
|
||||
if (!confirm_close())
|
||||
if (!confirmed && !confirm_close())
|
||||
return -EACCES;
|
||||
|
||||
err = sc_seco_chip_info(-1, &lc, NULL, NULL, NULL);
|
||||
|
||||
Reference in New Issue
Block a user